Q-Sonic 5 Path 12 shown"
Key Benefits
|
Capacity:
|
5600
ACFH to 7,500,000 ACFH (160 -
210,000 am³/h)
|
|
Diameters:
|
12" - 64"
|
|
Flange
Ratings:
|
ANSI 150# -
ANSI 2500#
|
|
Flow
Conditioning:
|
10D
upstream, 5D downstream straight length required. Optional
flow conditioning,
if used flow calibration suggested
|
|
Output:
|
Four pulse outs: 0
to 10,000 Hz; Modbus or ASCII RS 232/485
|
|
Pressure:
|
up
to 6170 psi, 425 bar
|
|
Turn-Down
Ratio:
|
typically:
60:1, depending on diameter
|
|
Type:
|
Spoolpiece
meter body, Multi-Path
|
|
Spec Sheet /
Brochure:
|
QSonic5.pdf
|
|
Website:
|
USA:
www.instrometinc.com
|
|
Additional
Information:
|
Ultrasonic
Gas Flow Meters Brochure
Test results Q.Sonic Brochure
Ultrasonic Gas Meters Handbook
Systems Handbook
|
 |
This is the top-of-the-line ultrasonic meter with
5 reflected paths (12 crossings of the gas flow) for maximum coverage
and accuracy. |
 |
It is used extensively for custody transfer and
increasingly as a reference standard in high accuracy calibration
facilities. |
 |
It exceeds the requirements of AGA-9. |
|