KEY BENEFITS

An efficient natural gas chromatograph analysis at an economical cost with low maintenance
Individual component molecular percentages required for custody transfer applications.  
Calculation of Energy Units, Gravity and Wobbe Index
Reproducibility: + or - .5 Btu @ nominal 1000 Btu (40MJ/M³)
+ or - .002 units @ nominal Specific Gravity of .610
Calibration Frequency: Automatic - every 24 hours
Manual - on demand
Power: 115 VAC 50/60 hz @1.5 amps
240 VAC 50/60 hz @ .75 amps
18 watts/hour nominal (180 watts peak during warm up)
Streams: Basic Analyzer:  Contains 1 sample stream and 1 calibration stream
Expansions:  to 2, 3, 4, 6, 10, 16 sample streams
Expansions:  to 2 or 3 calibration streams
Environmental Range: Temperature: 0 - 130°F (-18 to +55°C)
Moisture:  0 to 95% relative humidity, non-condensing
Safety Classifications: Designed for N.E.C. Class 1 Div 2
CENELEC EEx'd IIB T5
CE
Dimensions: Height 36 inches (91.44cm)
Width 24 inches (60.96cm)
Depth 12 inches (30.48cm)
Weight: Approximately 155 pounds (70.5kg)
Carrier Gas: Zero-grade helium at 120-140 psig (8.25-9.7 bar)
22 cc/minute usage
Analysis Frequency: 7.5 minutes

Gas Chromatograph:

Temperature controlled oven 130°C (No instrument air required)
Oven contains columns, detector and sample inject valve
Column Head pressure 100-120 psig
Sample Inject/Backflush Valve: 10 port diaphragm/piston valve
1,000,000 operations without overhaul
Columns: Micro-packed 1/16" 3 column set
Detector: Thermal conductivity type
Components Analyzed: Methane (CH4 ) Ethane (C2H6) Propane (C3H8) iso-Butane (iC4H10) iso-Pentane (isoC5H12) neo-Pentane (neoC5H12)
Nitrogen (N2) Carbon Dioxide (CO2) C6 Plus Normal-Butane (nC4H10) Normal- Pentane (nC5H12) .
Calculations: English (AGA)
Metric (ISO 6976)
System Alarms: High/low limits for total peak area, heating value, relative density and all measured components
Unknown alarm if peaks outside of retention time window
Alarm Action Indicated on printouts, LCD display or through communications port
Communication Port: #1 RS422 - User Port 4000ft (1200M) maximum distance.  For either PC direct or modem utilizing Black Box Converter to select RS422 or RS232 settings. (Black Box Standard with basic unit).  Connects from power supply board.
#2  RS232, RS422 or 485 - For RTU or Flow Computer. Modified modbus protocol.
Analyzer Display: LCD - 4 lines x 20 characters 
   - Indicates heating value, Sp.Gr., composition
  - Will allow to start and stop the analyzer as well as 
     activate and deactivate streams
Display may be mounted remotely
Analog Outputs (Optional):  4 minimum or 8 maximum (in groups of 4)
Any calculated variable may be defined for output to an analog channel
Available in 1-10 VDC, 1-5 VDC or as an additional option 4-20 ma current outputs
Sample Requirements: Vapor phase regulated from 0.5 to 30psig (0.05 to 2 bar)
Typical flow rate 10 to 30 ml/min
Brochure: Encal 2000.pdf

 

 