ULTRASONIC GAS METERS
 | This is the top-of-the-line ultrasonic meter with
5 reflected paths (12 crossings of the gas flow) for maximum coverage
and accuracy. |
 | It is used extensively for custody transfer and
increasingly as a reference standard in high accuracy calibration
facilities. |
 | It exceeds the requirements of AGA-9. |
 | Three reflected
paths (8 crossings) give this meter an excellent coverage of the gas
flow. |
 | It is designed
for custody transfer and meets the requirement of AGA-9. |
 |
New transducer design |
 |
Smaller footprint |
 |
| Face-to-face flange dimensions equal to comparable
diameter |
| turbine meters |
|
 | Available with either a single or dual path, it
is designed for check metering flow. |
 |
| Proven
accuracy (better that ±1.0%) repeatability and linearity |
| make it
one of the world's finest non-custody transfer meters |
|
 |
| Wide rangeability/turn down ratio 50:1 |
|
S.Sonic
 |
Economical Ultrasonic Solution |
 |
Low uncertainty (± 1.0%) with
excellent repeatability and linearity |
 |
Wide
rangeability/turn down ratio 50:1 |
 | A single path meter specifically designed for
measuring the flaring of natural gas. |
ROTARY GAS METERS
- IRM
1
 | Suitable for the measurement of all
non-corrosive gases |
 | Can be used for measurement where a high
accuracy is required over a wide operating range |
 | Internal by-pass included in all sizes |
IRM
3

 | Compact design that minimizes leakage of
gas through the measurement chamber and maximizes the volume transferred by
the impellers |
 | Certified for custody-transfer
applications |
TURBINE GAS METERS
Turbine Gas Meter Q &
QIC 
 | Suitable for all non-corrosive gases
 | Standard with LF & HF outputs
 | Series Q & QIC turbine meters are furnished with an integral oil pump
by means of which instrument oil can be forced through the bearing while the
meter is operating |
| |
Turbine Gas Meter X &
XIC

 |
Suitable for all non-corrosive gases |
 |
Standard with LF & HF outputs |
 |
The X turbine meter incorporates the patented X4X®
flow conditioner |
|
ENCAL 2000 |
(gas
chromatography)
|
- Encal 2000
 |
| An efficient natural gas chromatograph analysis at
an economical cost with low maintenance |
|
 |
| Individual component molecular percentages required
for custody transfer applications |
|
 |
| Calculation of Energy Units, Gravity and Wobbe Index |
|
FLOW COMPUTERS
Model 2000 Flow
Computer

 |
| Meter gas to the highest accuracy using either turbine
meters, ultrasonic meters, rotary meters or orifice plates |
|
 |
| Option of the conventional digital with analogue inputs
or a completely digital system giving the ultimate in system accuracy |
|
 |
| Expandable, enabling additional inputs, outputs and
serial ports where required |
|
 |
| An audit/alarm table is available to record logged
parameters |
|
|
TRU-THERM |
|
(combustion calorimeter) |
- Tru-Therm
 |
| Sorry, this product is no longer
available. |
| For service please contact mmaxwell@instrometinc.com |
| or call us at 1-800-795-7512. |
|
|